Lower investment by 25%
Fast installation only 2H
FC AC energy saving 30%
PUE less than 1.26
System emergency response protection
Biometrics authentication
Cascading available for rack
Saving room space 50%
Quiet operation less-than 55dB
DCIM 24H cloud O&M
Traditional miniaturized data centers face challenges such as high maintenance costs, long construction times, and the inability to monitor operating status in real time. PROSE created and innovated the Smart Micro Data Center to meet these requirements.
To meet the future deployment requirements of edge computing applications, the Smart Micro Data Center adopts a modular development concept. It offers the advantage of low cost, making it suitable for customers to install quickly and put into use in a timely manner.
The Smart Micro Data Center contains cabinets, power distribution systems, refrigeration systems, and cabling systems. In addition to meeting the need for continuous power to prevent data loss, the MDC can be accessed through TCP/IP, Cloud Apps, and other platforms so that customers can monitor the running status of the product in real time. Temperature and humidity monitoring systems, alongside an air-cooling system, provide a suitable working environment for customers' equipment. It also includes facial recognition, fingerprint recognition, and other authentication methods to provide robust data security protection.
| Item | Specification |
| Rack Height (Customizable) | 42U |
| Cabinet Dimensions, W × D × H (mm) | 600 (W) x 1200 (D) x 2050 (H) |
| Number of Cabinets | 1 |
| UPS Capacity (kVA) | 6 |
| Rated IT Load (kW) | 5.4 |
| UPS Input Voltage | 220/230 VAC, single-phase |
| UPS Rack Space | 2U |
| Battery Voltage | 192 VDC |
| Battery Backup | 15 minutes; one 5U battery pack containing 16 × 18 Ah VRLA batteries |
| PDB Rated Input Voltage | 220/230 VAC |
| PDB Rated Input Current | 50 A |
| Air Conditioner Cooling Capacity (kW) | One 3.5 kW nominal unit; 3.6 kW specified cooling capacity |
| Power and Environmental Monitoring System | One master environmental monitoring system with a touch-panel LCD dashboard, one smoke sensor, one temperature and humidity sensor, and a camera |
| PDU | One PDU with 20 IEC 320 C13 and 4 IEC 320 C19 outlets, rated at 32 A and 220 VAC, with a maximum power of 5 kW; intelligent monitoring is optional |
| Fire Suppression System | The fire suppression system is optional; this model’s listed configuration includes one automatic fire-suppression unit |
| Refrigerant | R410A |
| Color | Black or gray |
| Cabinet Construction | Welded frame with an integrated sealed-cabinet design |
| Compliance Standards | ANSI/EIA RS-310-D, IEC 297-2, DIN 41491, DIN 41494, and GB/T 3047.2-92 |
| IP Rating | IP5X |
| Display Panel | 10.1” Touch Panel LCD |
| Display Languages | English / Chinese |
| LED Lighting | Bi-color (red and blue) |
| Front Door | Toughened-glass door with a mechanical or fingerprint lock; supports face detection |
| Unlocking Methods | Remote control, authorized card, password, fingerprint, or mechanical key |
| Rear Door | Sheet-metal door |
| Static Load Capacity | Up to 2,200 kg |
| Safety Standard | RoHS |

42U, Seven-Cabinet Solution, 1xUPS 30 kVA, 4xAC 6.5 kW
_495x300.jpg)
42U,Two-Cabinet Solution, UPS 1x10 kVA, AC 1x6.5 kW

42U, Six-Cabinet Solution, 1xUPS 25 kVA, 3xAC 6.5 kW
_495x300.jpg)
42U, Four-Cabinet Solution, UPS 1x25 kVA, AC 2x12.5 kW
Welcome! Let us know how we can help, and we'll guide you to the right information or team.
You can fill out our Contact Sales Form here. A representative will contact you soon.
You can fill out our Technical Support Form here. A representative will contact you soon.
You can fill out our General Inquiries Form here. A representative will contact you soon.
You can find our Global Footprints here.
The default scope is the Product Category (more than 1391 products).
For non-product materials (support documents, press releases), select Search Website.