Efficient Deployment: 7-day commissioning, 50% shorter cycle, suitable for disaster relief "digital hub" and temporary event computing support.
Green & Energy-Saving: PUE< 1.26, AI temperature control, suitable for long-term use in remote mining and oil fields.
Safe & Stable: earthquake-resistant, ensuring operation in extreme environments for disaster relief and field work.
Strong Adaptability: compatible with finance, medical, etc., serving as traditional data center capacity supplement.
Low-Latency Response: Process data nearby, meeting edge computing's low-latency requirements.
The container data center solution designed by PROSE includes several functional units such as container box and seal assembly system, power supply and distribution system, IT cabinet system, refrigeration system, monitoring system, and fire protection system. After the container is pre-installed and pre-commissioned in the factory, it is transported to the destination. After the container is installed, the user can deploy the server by himself.
The use of container structure, not only the installation is simple and fast, to ensure that the user's business quickly online, but also to avoid building construction and other problems; The design of the container itself fully meets the outdoor operation conditions, not only with rain prevention, sunscreen, salt spray and other protective measures, to meet the national standard IP55 fire rating, but also fully adopted fire prevention and anti-theft measures.
| Type | Technical Parameters |
| Container System Size (W*D*H) | 3000mm*13716mm*3200mm(40 feet) |
| IP Level | IP55 |
| IT Cabinet Size (W*D*H) | 600mm x 1200mm x 2200mm (47U) |
| IT Cabinet QTY | 13 set |
| PDU | Standard PDU, vertically installed, 32A input, 20 x 10A+4 x 16A output |
| Integrated UPS | |
| Dimensions (W*D*H) (mm) | 600×1200×2000 |
| Rated Voltage | 380V |
| Frequency Range | 40-70 Hz |
| Battery Voltage | 192V |
| Display Screen | 7 in |
| UPS Power | 120KVA |
| Mains Output Power Distribution Module | The air conditioner power supply is 40A/3P MCB*5, the IT cabinet PDU power supply is 50A/1P MCB*10, and the maintenance socket is 16A/1P+NA RCD*1 |
| UPS Output Power Distribution Module | The PDU power supply of the IT cabinet is 50A/1P MCB*10, and the other branches (such as fire control, lighting, and new fans) are 10A/1P MCB*7 |
| Lithium Battery Cabinet | |
| Nominal Capacity (KWh) | 31.68(11 battery modules) |
| Cell Discharge Ratio | 4C |
| Rated Output Power (Discharge) (kW) | 110 |
| Communication Mode | TCP/IP, RS485 |
| System Display Mode | Touch screen |
| PAC Cabinet | |
| Air Conditioner Capacity | 25kw |
| Air Conditioner Size (W*D*H) (mm) | 300×1200×2000 |
| Machine Air Volume (M³/H) | 5000 |
| Energy Efficiency Ratio (EER) | 3.1 |
| Air Conditioner QTY | 5 |
| Fire Protection System | Fire alarm/linkage control/gas fire extinguishing controller, emergency stop button, manual/automatic transfer switch, fire sound and light alarm, bleed indicator light, emergency light, escape channel indicator light, safety exit indicator light, smoke detector, temperature detector, solenoid valve, pressure switch, fire sprinkler, fire gas cylinder and fire extinguishing agent (HFC-propane), etc |
| Dynamic Loop Monitoring System | Monitoring all-in-one, switch, 10-inch LCD touch screen, multi-loop precision power distribution monitoring system, battery monitoring system, UPS monitoring system, air conditioning monitoring system, environmental monitoring system (temperature and humidity detection, water leakage detection, hydrogen concentration detection), fire monitoring system (smoke detector, temperature detector), access control system (access controller, access card reader, IC Induction card, magnetic lock, exit button, emergency door button, etc.), video surveillance system (including 3pcs gun camera, 4pcs hemispherical camera, NVR hard disk burner, etc.), sound and light alarm device, etc |
| Cable Bridge | The cable tray is divided into strong current cable tray, weak current cable tray and optical fiber trough. The bridge is supported by the top bracket of the equipment. The weak current cable tray is mainly used for the weak current and signal cable routing of fire fighting and monitoring equipment. |
| Anti-Static Floor | Install ESD floors in the cold and hot aisles of containers. Place the ESD floor directly on the welded square pipe at the bottom of the container. The gap between the ESD floor and the sides of the container and cabinet is sealed with L-shaped or T-shaped aluminum alloy. The ESD floor is 200mm high, and the bottom is used for air conditioner pipe routing. |
| System Electromagnetic Shielding | The whole container adopts the way of strong current and weak current separate wiring to avoid strong current interference to the weak current part; After external cables are connected, the internal physical isolation mode is used to effectively isolate strong and weak electricity. |
Welcome! Let us know how we can help, and we'll guide you to the right information or team.
You can fill out our Contact Sales Form here. A representative will contact you soon.
You can fill out our Technical Support Form here. A representative will contact you soon.
You can fill out our General Inquiries Form here. A representative will contact you soon.
You can find our Global Footprints here.
The default scope is the Product Category (more than 1391 products).
For non-product materials (support documents, press releases), select Search Website.